Cable sealing system LS 90, conduit sealing system RS 90

Conduit sealing system RS 90

Conduit sealing system RS 90
Preview: Conduit sealing system RS 90
Conduit sealing system RS 90
  • 9459-02
  • 4013456536241
  • for EI90 fire-protection walls
  • for wall entries and feed-throughs
  • without use of fire-protection foam or putty
  • made of intumescent material
  • automatic room separation of the installation opening
  • unlimited building material shelf life
Min. wall thickness
100 mm
Installation opening (cavity wall)
35 mm
Installation opening (masonry)
32 mm
for conduits
M16 - M25
ETA approval
ETA-17-0449
for sound insulation walls up to
76 dB
Packaging inner/dispatch
10/100
Product information

Cable sealing system LS 90, conduit sealing system RS 90

Pipe and fire-retardant systems for safe closure of passages and entrances in fire-protection walls. The certified retardants are quick and easy to install and can even be superimposed on cables and pipes retrospectively (EI90). In addition, the cable sealing system can also be used as a wall outlet that enables the connection of electrical attachments.

  • Secure, visible, certified fire sealings
  • For wall feed-throughs and entries
  • Without filling and smoothing
  • Automatic sealing of the joints
  • For cables from Ø 5 - 15 mm
  • For conduits M16 - M25

Examples of applications for cable sealing system LS 90

Wall feed-through in plasterboard fire-protection wall.

Suitable for wall entry and wall outlet in dry construction fire protection wall.

Wall feed-through in a sand-lime brick fire-protection wall.

Wall feed-through in concrete fire-protection wall.

Secure wall outlet up to EI90 for connecting electrical attachments...

...like motion detectors.

Secure wall outlet up to EI90 for connecting electrical attachments...

...like wall lights.

Installation of cable sealing system LS 90 in cavity walls

Cut an installation opening Ø 20 mm using a cutter (e.g. KAISER hardened metal cutter Art. No. 1088-06) or drill.

To install, open the sealing sideways and slide it over the cable.

Press both sides of the sealing into each opening.

The cable sealings can be arranged vertically or horizontally to form a group with a centre distance of 50 mm.

Examples of applications for conduit sealing system RS 90

Wall feed-through in plasterboard fire-protection wall.

M16 - M25 wall entry, in plasterboard fire-protection wall with M25 conduit.

Wall feed-through in sand-lime brick fire-protection wall.

Wall feed-through in concrete fire-protection wall.

Installation of conduit sealing system RS 90 in cavity walls.

Cut a 35 mm installation opening using e.g. the KAISER cutter (Art. No. 1084-35).

To install, open the sealing sideways and slide over the conduit.

Press both sides of the sealing into each opening.

The conduit sealings can be arranged vertically or horizontally to form a group with a centre distance of 50 mm.

Installation of conduit sealing system RS 90 in solid walls

Make an installation opening using a Ø 32 mm drill.

Remove the strap for mounting in masonry (only when installing a conduit sealing in a masonry wall).

After installing the sealing, apply the identification tag.

The sealings can be used in masonry and concrete walls.

Certificates
Certificate

Classification report according to EN 13501-2:20216 for products in cross laminated timber walls

Certificate

LS 90 / RS 90 - Type approval (Z-19.53-2531)

Certificate

LS 90: 9459-01_RS 90: 9459-02 - Schallschutzgutachten

Certificate

Cable sealing system LS 90, conduit sealing system RS 90 - European Technical Assessment ETA

588.6 KB

Select download
Certificate

Test report for FlamoX®, LS 90 and RS 90, fire load from below

Download
Product data sheet

Conduit sealing system RS 90

Article no: 9459-02

Download
Brochure

Fire protection.

Box, housing and sealing systems for fire-protection walls and ceilings.

6.6 MB | 2024-02-28

Instruction

Cable Sealing System LS 90 / Conduit Sealing System RS 90

Assembly instructions, Art. No. 9459-01, 9459-02

1.3 MB | 2024-04-10

Performance declaration

Declaration of performance

Conduit sealing system RS 90, Art. No. 9459-02

1.8 MB | 2020-11-02

Select download
Performance declaration

KAISER Template Confirmation

Submission certificate from the specialist craft company for the client

32.2 KB | 2018-06-26