HWD 68+ one-gang box
NEW
HWD 68+ one-gang box
  • For F30-F90 or EI30-EI90, F30-B to F90-B fire-protection walls
  • also for directly opposing installation
  • from wall thicknesses of 100 mm
  • can be combined with each other and with the one-gang junction box
Article no: 9463-03
Depth: 49 mm For panel thicknesses up to: 7 - 40 mm Cut hole Ø: 68 mm
HWD 68+ one-gang junction box
NEW
HWD 68+ one-gang junction box
  • For F30-F90 or EI30-EI90, F30-B to F90-B fire-protection walls
  • also for directly opposing installation
  • from wall thicknesses of 125 mm
  • can be combined with each other and with the one-gang junction box
Article no: 9464-03
Depth: 60 mm For panel thicknesses up to: 7 - 40 mm Cut hole Ø: 68 mm
Support connector
Support connector
  • For fully insulated through-wiring in combinations
  • Smokeproof
  • for Art. Nos. 9463-03, 9464-03
Article no: 9060-68
Fire protection PROTECT® one-gang junction box for solid wood
NEW
Fire protection PROTECT® one-gang junction box for solid wood
  • For F30-B to F120-B solid wood elements
  • Mounting with rib fixing
  • Cable entry enables tolerance compensation of the cable route
  • Also for directly opposing installation
  • Preserves the sound insulation properties of the solid wood elements
Article no: 9464-05
Depth: 60 mm Cut hole Ø: 74 mm Screw spacing: 60 mm
HWD 90 one-gang box
HWD 90 one-gang box
  • For F30-F120 or EI30-EI120 and F30-B / F60-B fire-protection walls
  • Also for I30 - I90 installation shafts / installation ducts
  • also for F30-B - F60-B timber frame or timber panel construction walls
Article no: 9463-01
For panel thickness: 7 - 40 mm Depth: 44 mm Cut hole Ø: 74 mm
HWD 90 one-gang junction box
HWD 90 one-gang junction box
  • For F30-F120 or EI30-EI120 and F30-B / F60-B fire-protection walls
  • Also for I30 - I90 installation shafts / installation ducts
  • also for F30-B - F60-B timber frame or timber panel construction walls
Article no: 9464-01
For panel thickness: 7 - 40 mm Depth: 54,5 mm Cut hole Ø: 74 mm
FlamoX® fire-protection putty
FlamoX® fire-protection putty
  • Building material forming an insulating layer
  • for filling joints as well as bonding board materials
  • Type 9400
  • Working time 30 mins.
  • Can be stored up to 12 months
Article no: 9400-05
DIBt approval: Z-19.11-1583 Contents: 300 ml
Support connector, air-tight, halogen-free
Support connector, air-tight, halogen-free
  • For fully insulated through-wiring in combinations
  • to make air-tight combinations
  • for Art. Nos. 9066-01/12, 9068-01, 9263-..., 9264-… , 9062-02/-77, 9062-94/-74, 9268-94/-74, 9266-22/-77
Article no: 9060-78
Halogen-free: Yes
Electronics box HWD 90
Electronics box HWD 90
  • For cables and conduits up to M25
  • Also for use as a double box
  • For fire-protection walls F30-F120 or EI30-EI20
  • minimum wall thickness 100 mm
  • For equipment inserts and electronic components
  • Tunnel twin-chamber box with enclosed separator wall and cover that can be wallpapered over.
  • Can be combined with each other and also with HWD 90 one-gang junction boxes
Article no: 9462-94
For panel thickness: 7 - 40 mm Depth: 70 mm Cut hole Ø: 2 x 74 mm
Ceiling box HWD 30
Ceiling box HWD 30
  • for fire protection ceilings F30-F90 or EI30-EI90
  • For F30 (EI30) non-insulated fire-protection ceilings
  • For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
  • for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100
Article no: 9463-50
Depth: 44 mm Cut hole Ø: 74 mm Screw spacing: 60 mm