Flush-mounting fire-protection box
Flush-mounting fire-protection box
  • for F30-F120 or EI30 - EI120 fire-protection walls
  • also for minimum remaining wall thickness ≤ 60 mm
  • also for directly opposing installation
  • with 4 screw domes and 2 expanding claw fields
Article no: 1564-01
Depth: 60 mm Fixing screw spacing: 60 mm Tube entries up to M25: 6
HWD 90 one-gang box
HWD 90 one-gang box
  • For fire-protection walls F30-F120 or EI30 - EI120
  • Also for installation shafts / installation ducts I30 - I90
  • also for timber frame or timber panel walls EI30-EI60
Article no: 9463-01
For panel thickness: 7 - 40 mm Depth: 44 mm Cut hole Ø: 74 mm
HWD 90 one-gang junction box
HWD 90 one-gang junction box
  • For fire-protection walls F30-F120 or EI30 - EI120
  • Also for installation shafts / installation ducts I30 - I90
  • also for timber frame or timber panel walls EI30-EI60
Article no: 9464-01
For panel thickness: 7 - 40 mm Depth: 54,5 mm Cut hole Ø: 74 mm
FlamoX® fire-protection putty
FlamoX® fire-protection putty
  • fire-retardant material
  • for filling joints and gluing board materials
  • type 9400
  • max. working time 30 mins.
  • can be warehoused for up to 12 months
Article no: 9400-05
DIBt approval: Z-19.11-1583 Contents: 300 ml
Support connector, air tight, halogen-free
Support connector, air tight, halogen-free
  • For fully insulated through-wiring in combinations
  • to make air-tight combinations
  • for Art. Nos. 9066-01/12, 9068-01, 9263-..., 9264-… , 9062-02/-77, 9062-94/-74, 9268-94/-74, 9266-22/-77
Article no: 9060-78
Halogen-free: Yes
Electronics box HWD 90
Electronics box HWD 90
  • For cables and conduits up to M25
  • Also for use as a double box
  • For fire-protection walls F30-F120 or EI30-EI20
  • minimum wall thickness 100 mm
  • For equipment inserts and electronic components
  • Tunnel twin-chamber box with enclosed separator wall and cover that can be wallpapered over.
  • Can be combined with each other and also with HWD 90 one-gang junction boxes
Article no: 9462-94
For panel thickness: 7 - 40 mm Depth: 70 mm Cut hole Ø: 2 x 74 mm
One-gang box HWD 68
One-gang box HWD 68
  • for F30-F90 or EI30-EI90 fire-protection walls
  • also for directly opposing installation
  • minimum wall thickness 100 mm
  • can be combined with each other and with the one-gang junction box
Article no: 9463-02
Depth: 49 mm Cut hole Ø: 68 mm Screw spacing: 60 mm
One-gang junction box HWD 68
One-gang junction box HWD 68
  • for F30-F90 or EI30-EI90 fire-protection walls
  • also for directly opposing installation
  • minimum wall thickness 125 mm
  • combinable with each other and with the one-gang box
Article no: 9464-02
Depth: 62 mm Cut hole Ø: 68 mm Screw spacing: 60 mm
Support connector
Support connector
  • For fully insulated through-wiring in combinations
  • Smokeproof
  • for Art. Nos. 9463-02, 9464-02
Article no: 9060-68
Ceiling box HWD 30
Ceiling box HWD 30
  • for fire protection ceilings F30-F90 or EI30-EI90
  • For F30 (EI30) non-insulated fire-protection ceilings
  • For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
  • for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100
Article no: 9463-50
Depth: 44 mm Cut hole Ø: 74 mm Screw spacing: 60 mm
Ceiling junction box HWD 30
Ceiling junction box HWD 30
  • for fire protection ceilings F30-F90 or EI30-EI90
  • For F30 (EI30) non-insulated fire-protection ceilings
  • For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
  • for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100
Article no: 9464-50
Depth: 54,5 mm Cut hole Ø: 74 mm Screw spacing: 60 mm
Fire-protection cover HWD 30-120
Fire-protection cover HWD 30-120
  • For one-gang boxes/one-gang junction boxes and ceiling boxes HWD 90, HWD B15, HWD 30 and HWD 68
  • Fire resistance class in accordance with ceiling or wall protection (F30-F120 and EI30-EI120)
  • F30-F120 and EI30-EI120 function in conjunction with the one-gang box/one-gang junction box HWD 90
  • F30 and EI30 function in conjunction with ceiling junction box HWD 30
  • F30-F60 and EI30-EI60 function in connection with one-gang/one gang junction box HWD 68
Article no: 1184-94
DIBt approval: Z-19.21-1788
1 From 2