Fire protection sealing for shipbuilding

B15 PROTECT® multiple sealing

B15 PROTECT® multiple sealing
  • 9459-15
  • 4013456582040
  • For shipbuilding walls and ceilings in the category B15 separation planes
  • For pre-assembled cables
  • For fire protection sealing of cable entries
  • Without the use of fire protection putty
  • Self-supporting sealing through insulation-forming material
Depth
25 mm
Installation opening Ø
50 mm
For sheet thicknesses
0,5 – 0,8 mm
Cable entries Ø 4 to 9.5 mm
2
Cable entries Ø 4 to 12.5 mm
2
Halogen-free
Yes
Packaging inner/dispatch
5/50
Product information

Fire protection sealing for shipbuilding

The B15 PROTECT® fire protection sealing guarantees fire protection-related room separation in shipbuilding walls and ceilings. Fire, smoke and high temperatures are prevented from spreading due to the intumesce material that forms an insulating layer in the event of fire. Cable entries are safely, permanently and reliably sealed with the B15 PROTECT® multiple sealing and B15 PROTECT® cable sealing, thereby guaranteeing a room separation of 30 minutes.

  • For ship cabin walls and ceilings B15
  • For cables from Ø 4 - 12.5 mm multiple sealing
  • For cables from Ø 4 - 15 mm cable sealing
  • Ideal for pre-assembled cables
  • Safe, certified fire protection solution
  • Certified by DNV applied
  • Without the use of fire protection putty
  • Toolless installation
  • Maintains the wall's sound insulation protection

Application examples

For cable entries through shipbuilding walls with category B15.

As well as shipbuilding ceilings B15.

Installation for wall thicknesses of 25 mm to 50 mm.

Ceiling mounting also for 25 mm to 50 mm panel thickness.

Processing instructions

Two-part fire protection systems B15.

For the fire protection sealing of individual cables or cable bundles in walls...

...and ceilings with 4 - 12.5 mm cable diameter.

Can also be used in a group arrangement.

Assembly - B15 PROTECT® multiple sealing

Create installation opening Ø 50 mm.

Feed-through up to 4 cables with a diameter of 4 - 12.5 mm.

Place both half parts of the B15 PROTECT® multiple sealing around the cables, snap into place,...

...and press it into the component opening until it audibly clicks into place.

Certificates
Certificate

Classification report according to EN 13501-2:20216 for products in cross laminated timber walls

Download
Product data sheet

B15 PROTECT® multiple sealing

Article no: 9459-15

Download
Brochure

INNOVATIONS 2024/2025

Centrepiece of every installation

4.2 MB | 2024-03-05

Brochure

Electrical installation in shipbuilding.

Versatile, safe and certified.

3.6 MB | 2023-09-05