Central transition casing

Moisture-proof cover ALU (330 x 120 x 8 mm) for Art. No. 9914.10

Moisture-proof cover ALU (330 x 120 x 8 mm) for Art. No. 9914.10
Preview: Moisture-proof cover ALU (330 x 120 x 8 mm) for Art. No. 9914.10
Moisture-proof cover ALU (330 x 120 x 8 mm) for Art. No. 9914.10
  • 9914.10.03
  • 7611614453835
Material
Aluminium anodised
Length
330 mm
Width
120 mm
Height
4 mm
Screws
6
For type number
9914.10
Dispatch
50
Product information

Central transition casing

The new central transition box for use in on-site mixed concrete ceilings or factory prefabricated element ceilings is used for the central connection of conduits of different diameters. As a central feed-in point, it enables a clean transition to circuit distribution boxes and cable routing systems, allowing, for example, all the supply cables required for the electrical installation of a flat to be brought together at one transition point.

  • For leaving out several cables, e.g. above an electrical distribution board located in the lightweight wall or surface-mounted
  • For system magnetic, adhesive or nail fastening
  • Conduit entries for Ø 20 mm, Ø 25 mm and Ø 32 mm on the long sides, up to Ø 63 mm on the short sides
  • Positioning of the conduit entries above the first reinforcement layer or the top of the filigree ceiling
  • Can be connected in a row as often as required

Application examples

Numerous entries for conduits from Ø 20 mm to Ø 63 mm.

The central transition casing for the exit of several conduits, e.g. is located in above in the lightweight wall...

...or surface-mounted electrical distribution...

...as well as cable routing systems.

Processing instructions

Fixing by means of steel nails.

Fixing by means of KAISER system magnet (Art. No. 1299-69) or KAISER system magnet PLUS (Art. No. 1299-70).

Fixing by means of hot glue.

If required, several central transition casings can be lined up next to each other.

Installation

The flat front section is pre-assembled with nails for quick and easy fixing to the ceiling formwork.

Latch the centre transition casing onto the front section.

If required, several central transition casings can be joined together by opening the Ø 40 mm to Ø 63 mm side entries.

The required conduit entries can be opened with the KAISER step drill (Art. No. 1284-32)...

...or opened with a screwdriver and hammer.

The side entries Ø 40 mm to Ø 63 mm can be drilled out using a hole saw.

If a large number of different conduits are inserted, four large segments can be opened using a screwdriver and hammer.

Numerous entries for conduits from Ø 20 mm to Ø 63 mm.

After formwork removal, the plaster skin is opened with the blow of the hammer and, if necessary, a screwdriver.

The upper frame (Art. No. 9914.10.68) can be used for suspended ceiling insulation. Multiple times if required.

The plastic screw cover (Art. No. 9914.10.02) with six screws supplied is available for a clean room separation...

...or the wet lid made of aluminium (Art. No. 9914.10.03) with anodised surface and six stainless steel screws supplied.

Download
Product data sheet

Moisture-proof cover ALU (330 x 120 x 8 mm) for Art. No....

Article no: 9914.10.03

Download
Flyer

Central transition box. For universal conduit entries.

For on-site mixed concrete and precast concrete.

378.8 KB | 2024-02-27