Cavity wall

  • Complete system for all cavity wall applications
  • Fast-installation FX4 technology for time-saving installation
  • Air-tight installation in line with EnEV energy-saving ordinance.
  • ECON® technology: air-tight one-gang boxes and one-gang junction boxes for toolless cable and conduit entries
  • HWD fire-protection box for fire-protection walls and ceilings and also shipbuilding walls
Complete system for all cavity wall applications Fast-installation FX4 technology for time-saving installation Air-tight installation in line with EnEV energy-saving ordinance. ECON®... read more »
Close window
Cavity wall
  • Complete system for all cavity wall applications
  • Fast-installation FX4 technology for time-saving installation
  • Air-tight installation in line with EnEV energy-saving ordinance.
  • ECON® technology: air-tight one-gang boxes and one-gang junction boxes for toolless cable and conduit entries
  • HWD fire-protection box for fire-protection walls and ceilings and also shipbuilding walls
Choice of category
Main category
Sub-category
Filtering
Cut hole Ø
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
  •   Cut hole Ø:
Halogen-free
  •   Halogen-free:
Diameter
  •   Diameter:
  •   Diameter:
  •   Diameter:
  •   Diameter:
Length
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
  •   Length:
Width
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
  •   Width:
Depth
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
  •   Depth:
Air-tight
  •   Air-tight:
Installation type
  •   Installation type:
  •   Installation type:
  •   Installation type:
  •   Installation type:
  •   Installation type:
  •   Installation type:
  •   Installation type:
  •   Installation type:
  •   Installation type:
Field of application
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
  •   Field of application:
Results filtered according to:
3 From 19
Results filtered according to:
No results were found for the filter!
O-range® one-gang box, Depth 49 mm
O-range® one-gang box, Depth 49 mm
  • with holding ring
Article no: 9063-02
For panel thickness: 7 - 40 mm Depth: 49 mm Cut hole Ø: 68 mm
O-range® one-gang box, Depth 49 mm, halogen-free
O-range® one-gang box, Depth 49 mm, halogen-free
  • with holding ring
Article no: 9063-78
For panel thickness: 7 - 40 mm Depth: 49 mm Cut hole Ø: 68 mm
O-range® one-gang junction box, Depth 62 mm
O-range® one-gang junction box, Depth 62 mm
  • with holding ring
Article no: 9064-02
For panel thickness: 7 - 40 mm Depth: 62 mm Cut hole Ø: 68 mm
O-range® one-gang junction box, Depth 62 mm, halogen-free
O-range® one-gang junction box, Depth 62 mm, halogen-free
  • with holding ring
Article no: 9064-78
For panel thickness: 7 - 40 mm Depth: 62 mm Cut hole Ø: 68 mm
One-gang box, Depth 35 mm
One-gang box, Depth 35 mm
  • with holding ring
Article no: 9061-00
Depth: 35 mm Cut hole Ø: 68 mm For panel thickness: 7 - 28 mm
One-gang box, Depth 35 mm, halogen-free
One-gang box, Depth 35 mm, halogen-free
  • with holding ring
Article no: 9061-77
Depth: 35 mm Cut hole Ø: 68 mm For panel thickness: 7 - 28 mm
Two-gang junction box, Depth 47 mm
Two-gang junction box, Depth 47 mm
  • for 2 electrical inserts or 1 block insert
  • with cover (Art. No. 9062-90), for use as a junction box
  • use separator wall to separate electrical circuits Art. No. 9062-22
  • with holding ring
Article no: 9062-02
For panel thickness: 7 - 40 mm Depth: 47 mm Cut hole Ø: 2 x 68 mm
Two-gang junction box, Depth 47 mm, halogen-free
Two-gang junction box, Depth 47 mm, halogen-free
  • for 2 electrical inserts or 1 block insert
  • with cover (Art. No. 9062-90), for use as a junction box
  • use separator wall to separate electrical circuits Art. No. 9062-22
  • with holding ring
Article no: 9062-77
For panel thickness: 7 - 40 mm Depth: 47 mm Cut hole Ø: 2 x 68 mm
Replacement cover 145 x 75 mm
Replacement cover 145 x 75 mm
  • for junction box Art. No. 9062-02
Article no: 9062-90
Length: 145 mm Width: 75 mm
One-gang box for thin boardings, depth 41 mm
One-gang box for thin boardings, depth 41 mm
  • for boardings that do not permit any countersinking
  • with thin holding ring
  • Protection class IP 3X
Article no: 9068-04
For panel thickness: 0,2 - 40 mm Depth: 41 mm Cut hole Ø: 68 mm
One-gang box for thin panelling, depth 41 mm, halogen-free
One-gang box for thin panelling, depth 41 mm, halogen-free
  • for boardings that do not permit any countersinking
  • with thin holding ring
  • Protection class IP 3X
Article no: 9068-74
For panel thickness: 0,2 - 40 mm Depth: 41 mm Cut hole Ø: 68 mm
One-gang junction box for thin boardings, depth 61 mm
One-gang junction box for thin boardings, depth 61 mm
  • for boarding that does not permit countersinking (e.g. metal-covered boarding)
  • with thin holding ring
Article no: 9068-03
For panel thickness: 0,2 - 40 mm Depth: 61 mm Cut hole Ø: 68 mm
3 From 19