EnoX® installation housing

EnoX® sealing foam frame

EnoX® sealing foam frame
Preview: EnoX® sealing foam frame
EnoX® sealing foam frame
  • 9350-99
  • 4013456533011
  • for fixing onto the EnoX® housing
  • for sealing the moisture barrier to the housing
Dispatch
10
Product information

EnoX® installation housing

EnoX® housing for luminaires and other devices in ceilings and walls which are produced in a lightweight design with an air-tight building shell. Variable installation space when there is insufficient room to install electrics in the insulation level.

  • Air-tight installation in line with GEG energy-saving ordinance.
  • No additional installation level is necessary
  • For ceilings and walls in renovated and new buildings
  • Toolless cable and conduit entry
  • Thermally-protected installation space 300 x 200 x 55 mm
  • ECON® technology for air-tight and toolless insertion
  • FX⁴ technology for fast cavity wall installation

Installation technology for low-voltage luminaires

Temperature profile for room temperature 23°C

Low-voltage 35 W cool beam

Low-voltage 35 W Alu

Low-voltage 50 W Alu

Example of installation

Technical processing instructions / standards

  • use only certified (EN 60598) luminaires which are suitable for direct installation on normally flammable materials
  • only for insulation material with heat resistance > 250 °C
  • use only tested heat-resistant cables (N2 GMH 2G) and temperature-resistant terminals (e.g. T100)
  • use of electrical safety transformers up to 105 VA
  • max. 35 W Cool-Beam, 50 W aluminium reflector, 6.6 W LED luminaires

Examples of use

The EnoX® luminaire and loudspeaker housing can be mounted on the rafters in alternating...

...as well as inside the rafter behind the vapor barrier film...

...or mounted in a cut-out in an OSB panel.

EnoX® creates flexible space for the electrical installation in the insulation level.

Mounting instructions

The EnoX® housing is installed within or on the rafters using the timber or metal joist. In accordance with the cavity wall box principle, the housing is fixed to the joist or to an OSB panel using the FX⁴ strap fastening system. The cut-off moisture barrier is made air-tight again using sealing adhesive foil or the KAISER sealing foam frame. Before attaching the boarding, completely remove the moisture barrier foil from the housing interior. Together with the moisture barrier, the EnoX® housing now forms one unit to ensure air-tight installation in accordance with the GEG energy-saving ordinance.

Timber joist on the rafter

Timber joist inside the rafter

Installation using OSB panel.

Making the installation opening for luminaires

Installation technology

In sloping roofs, for example, EnoX® acts as an air seal and creates a flexible space for the electrical installation in the insulation base.

Application example: LED luminaires

Download
Product data sheet

EnoX® sealing foam frame

Article no: 9350-99

Download
Brochure

Energy efficiency.

Electrical installation for energy-saving buildings.

6.8 MB | 2024-02-28

Brochure

Free space.

For luminaires, loudspeakers and installation accessories.

8.8 MB | 2020-03-05

Flyer

EnoX®

Luftdichte Elektro-Installation in der Dämmebene.

Instruction

Installation housing EnoX®

Assembly instructions

2 MB | 2020-09-10